Water dispenser with flow control
 
FEEDER ADJUSTABLE WATER FLOW is a device equipped with a microprocessor controller, designed to regulate the flow of water dispensed. Particularly useful is the dispensing process water administered continuously by flow rate, eg the production of pasta.
WATER DISPENSER is designed to collect water from the water supply network. The device is continuously measured in both flow rate and flowing water and its temperature and presents the information on the displays. Dispenser continuously adjusts the flow rate of water.
Dispensers of our production are new, yet proven and tested product that is constantly improved and developed based on feedback from existing users.
Control unit is an electronic dispenser USP microprocessor controller designed and manufactured by our company based on the latest electronics. Driver software is also done in our company so we can immediately respond to the suggestions reported by current users.
Actuators (solenoid valves, flow sensors) mounted dispensers are of the highest quality and are manufactured by world-renowned companies such as: Rossweiner, Danfoss, Esco, Hankook, and others.
| water connections | How to Connect | Screw connection ½ / ¾ inch or hose ½ / ¾ inch |
| programming | The programming | Using the keypad, 4 function keys, 5 keys to set values, the two modes of operation |
| programmable parameters: temperature correction flow coefficient |
+/- 5 °C 10.0 - 90.0 typical: 74.0 for ½ inch 18.0 for ¾ inch |
|
| Setting | set to size: The flow rate |
0.1 - 60.0 l/min. |
| water pressure | maximum | 5 bar |
| flow | minimum | 0.1 l/min |
| maximum | 60.0 l/min | |
| measurement error | +/-1.5% | |
| Power Supply | voltage | 230VAC +/-10% 50Hz |
| Maximum power consumption | 8VA | |
| alarms | Over range (alarm at 97 deg C) | Intermittent light and audible signal |
| Temperature sensor failure | Intermittent light and audible signal | |
| No signal from flow sensor with an open discharge | Intermittent light signal | |
| Presentation by signals from the sensor with a closed discharge | Continuous light signal and the intermittent sound | |
| other | memory | Protection against loss of supply voltage, nonvolatile flash memory parameter setting value Memory of last 100 operations |
| digital display | 3 + 2 digits (red 14 mm) | |
| degree of protection | From the front IP54, IP20 total | |
| installation Category | I | |
| degree of pollution | I | |
| fuse | 2 x 600 mA type M or T | |
| operating temperature | 0 - 45 ° C | |
| humidity | 80% without condensation | |
| weight | 3.2 kg - 1/2 inch policarbonate 4 kg - 1/2 inch stainless steel 4.7 kg - 3/4 inch policarbonate 5,5 kg - 3/4 inch stainless steel |
|
| Case Size |
WxSxG (190x380x130mm) PC WxSxG (210x380x170mm) st. steel |
|
| housing material | PC (polycarbonate) or stainless steel | |
| Hole Spacing | 355 mm PC, 335 st.steel | |
| Faceplate Color | gray |