Industrial Automatics - controls, measurement, regulators, sensors...

Microprocessor Controller USPP-TCF

USPP-TCF is a microprocessor controller which controls temperature and measures time. USPP-TCF is designed for tunnel ovens. Controlling method is based on PID or hysteresis type. Since the controller is universal, it can be used everywhere, where regulation of temperature and measuring of time is needed. Device is fully programmable and all programmed parameters are stored in non-volatile memory. Controller can be installed both in new and used up ovens.

USPP-TCF controller is two-channel regulator. It controls temperature in two different places in an oven. The device reads temperature from two sensors and controls the work of relays.

Additionally USPP-TCF measures the time needed by the conveyor belt to go through the oven, or the frequency of inverter.

Measured values of temperature and time (or frequency) are presented on displays in real-time. There are additional LEDs on the front panel that indicate whether output is on or off. Other LEDs are used to signal alarm states. There are separate buttons to control additional functions like switching light, ventilation, etc. Device has a sound signalling device to indicate the end of measured time.
Microprocessor Controller USPP-TCF

Inputs Two temperature measurement inputs for resistance sensors, thermocouples and standard signals
Alarm input
Measurement input 0,1% of measurement range- 10-bit analogue to digital converter
Outputs Four relay outputs 5A/250VAC, resistance load
Two voltage outputs
User interface 12 keys
LED display 3+2 digits (red, or green - 14mm)
Alarms Alarm value exceeded
Sensor damage
Damage in power circuit
Power supply Voltage
Power consumption
230VAC, 24VAC, 12VAC, 12VDC
4VA
Enclosure and assembly Degree of protection Front IP54, total IP20
Operating temperature 0 - 60 ° C
Maximum humidity 80% without condensation
Weight 950g
Enclosure dimensions HxWxL
(96x96x120mm) - Metal enclosure
(96x96x100mm) - Plastic enclosure
(Strengthened Noryl)
Assembly method Table mounted
Assembly slot size HxW (91x91mm)
Maximum assembly panel thickness 8mm


External connections
Microprocessor Controller USPP-TCF - connections

Measurement input type
Code Sensore Range
1 Thermocouple J 0 - 800°C
2 Thermocouple K 0 - 1200°C
3 Thermocouple N 0 - 1300°C
4 Pt100 -200 - 750°C
5 0 - 1 V -------
6 0 - 20 mA -------
1 4 - 20 mA -------

    USPP-TCF-   X - X - X - X      
        |   |   |   | _ Power supply  
        |
|
|
|
  |
|
|
|
  |
|
|
|
      1: 230 VAC
2: 24 VAC
3: 12 VAC
4: 12 VDC
 
        |   |   |          
        |   |   | _ _ _ Output type  
        |
|
|
  |
|
|
          S: relay
N: voltage
 
        |   |              
        |   | _ _ _ _ _ Sensor type  
        |               see table  
        |                  
        | _ _ _ _ _ _ _ Enclosure type  
                        M: Metal
P: Plastic
 
                           
                           
                           
                           
Ordering example:
USPP-TCF-M-4-S-1
Universal tunnel oven regulator USPP-TCF, metal enclosure, sensor PT100, relay output, power supply 230 VAC
                           

Measurement input type
Code Sensore Range
1 Thermocouple J 0 - 800°C
2 Thermocouple K 0 - 1200°C
3 Thermocouple N 0 - 1300°C
4 Pt100 -200 - 750°C
5 0 - 1 V -------
6 0 - 20 mA -------
1 4 - 20 mA -------
© TELDREAM